Features

  • Skin friendly NeoBond® Hydrocolloid baseS
  • Secure positioning flaps designed to relieve stress on tubes and help prevent dislodgement
  • Accommodates two catheters

The secure positioning flaps on this innovative umbilical catheter holder keep tubes from dislodging and reduce stress on the tubing. NeoBridge features a skin-friendly NeoBond Hydrocolloid base, and its flaps are designed to open and close repeatedly. Each NeoBridge can accommodate two catheters, and the clear flap allows for easy visibility. This product is available in micro, small, and large sizes.

Directions for Use

Preparation:
  • After the catheter has been inserted, clean and dry skin per hospital protocol.
  • Note: It is important for skin to be as clean and dry as possible. NeoBridge will not adhere properly to moist skin or hair. Oils and lotions will also adversely affect adhesion.
  • DO NOT USE ALCOHOL.
Application:
  • Step-1: Before removing the plastic liner, you must actively warm the hydrocolloid adhesive. To do this, you can use one of the following warming techniques: first, hold it between the palms of your hands for at least 60 seconds; alternatively, hold it near a radiant warmer for 10-15 seconds; or, you can hold it against a chemical heel warmer for 10-15 seconds.
  • Step-2: Discard white, paper liner, then peel and discard clear, plastic liner from hydrocolloid base.
  • Step-3: With slit on right side and wider end of hydrocolloid base facing patient’s head, slip catheter through center of NeoBridge.
  • Step-4: Apply base to skin and hold in place for 60 seconds to ensure proper adhesion.
  • Step-5: Peel and discard the frosted liner from the top half of the flap. Bring flap up and affix catheter(s) to flap in an arch or U shape to minimise tension with catheter(s) exiting out the side of the flap.
  • Note: Do not extend the catheter(s) into the green area of the flap. If using two catheters, have one catheter exit each side of the flap.
  • Step-6: Peel and discard the frosted liner from the bottom half of the flap. Bring the flap up to align the green area of bottom half with the green area of top half and press firmly together, enclosing catheter(s) between adhesive flaps.
  • Step-7: Pull flaps apart to remove or reposition catheter(s) as needed, then close to secure.
Removal:
  • Step-1: Replace NeoBridge every 5 days or per hospital protocol, whichever is sooner.
  • Step-2: Pull flaps apart to remove catheter(s).
  • Step-3: Saturate NeoBridge with water or saline.
  • Step-4: Slowly peel NeoBridge away from skin as you swab the skink with water or saline
INDICATIONS FOR USE
  • The NeoBridge anchors and supports umbilical catheters and is intended for use with pediatric patients, including neonates, infants, and children.
CAUTIONS & WARNINGS
  • Federal law restricts this device to sale by or on the order of a physician.
  • Trained healthcare professionals should provide continuous, direct supervision while using NeoBridge.
  • Discontinue use immediately if skin irritation occurs.
  • NeoBridge will not adhere properly to moist skin or hair. Oils and lotions will adversely affect adhesion.
  • Do not use alcohol to clean skin prior to application.
  • Single patient use only.



Specifications

Cat No. Size Qty/Unit
N700 Micro 20/box
N701 Small 20/box
N702 Large 20/box
Downloads

pdf icon Sell Sheet

Related Products

NeoBridge® Umbilical Catheter Holder

Umbilical Catheter Holder

Learn More
NeoHug® Utility Device Holder

Utility Device Holder

Learn More
NeoHeart® ECG Electrode Pads

ECG Pad

Learn More
NeoLead® Radiolucent ECG Leads

ECG Electrodes

Learn More